Address
304 North Cardinal
St. Dorchester Center, MA 02124
Work Hours
Monday to Friday: 7AM - 7PM
Weekend: 10AM - 5PM
Address
304 North Cardinal
St. Dorchester Center, MA 02124
Work Hours
Monday to Friday: 7AM - 7PM
Weekend: 10AM - 5PM
The YSM series double skin air handling unit (AHU) consists of 81 models with air volumes ranging from from 1,200 ~ 99,180m3/h and standard internal static pressures as high ±1000 Pa (for 25/50mm thickness panel), to ensure maximum flexibility and the best solution for your application.
YSM air handling units are modular in design and can be manufactured in varied configurations, with a wide selection of components, to meet customer requirements. Units are suitable for shopping malls, hotels, office buildings etc. which in today’s world demand improved indoor air quality requirements, and can also adapted to the hygiene and performance requirements of sectors and industries that depend on ultra-cleanliness, such as hospitals, pharmaceuticals, electronic factory etc.
YSM has two series YSM-M and YSM-P with different casing design and casing performance to meet various customer needs.
Custom Made
Powerful Function
Professional Software for Coil Selection
Comprehensive Output Reports
Length (Module) (for reference only)
Damper located at front: L=5MDamper located at top or side: L=Dmp_L=5M~32M(Dmp_L is length module following air flow direction at side or top damper, determined by model and damper air flow rate)
Optional
Damper arrangement, Flange, Manual damper, Motorized damper without actuator, Motorized damper with On-Off or analog signal actuator, Access door, Marine light
Length (Module) (for reference only)
L=Dmp_L=5M~32M(Dmp_L is max length module following air flow direction at side or top damper, will be determined by model and damper air flow rate)
Optional
Damper arrangement, Fresh air ratio, Flange, Manual damper, Motorized damper without actuator, Motorized damper with On-Off or analog signal actuator, Access door, Marine light.
Length (Module) (for reference only)
L=EA_Dmp_L +OA_Dmp_L=10M~36M (EA_Dmp_L is length module of exhaust air damper following air flow direction, OA_Dmp_L is length module of outdoor air damper following air flow direction, and it is determined by model and damper air flow rate)
Optional
Damper arrangement, Exhaust air ratio, Flange, Manual damper, Motorized damper without actuator, Motorized damper with On-Off or analog signal actuator, Access door, Marine light
Length (Module) (for reference only)
L=4M 300mm Bag filterL=5M Plate filter+300mm Bag filterL=6M 500mm Bag filterL=7M Plate filter+500mm Bag filter
Optional
G3/G4 Plate filter; G3/G4/F5/F6/F7/F8 Bag filter,Bag filter length 300/500mm, Single bag filter,Plate and bag combination filter,Without filter (only offer bag filter frame),Spare filter, Pressure difference gauge, Access door
Length (Module) (for reference only)
L=5M~11M1. It is determined by coil row and combination mode2. Evaporative humidifier, droplet eliminator installed in coil segment, and does not occupy a separate segment
Optional
1~12R Cooling coil+1~4R Heating coil,1~12R Cooling coil+1~2R Steam coil, Dual cooling coil, Steel/copper header, Piping direction, Droplet eliminator, 50/100/150/200mm Evaporative humidifier (EV), Humidifier brand